References
[1] A Ckers, P., White, W.R., Perkins, J. A. and Hanison A. J.M., “Weirs and Flumes for Measurement” John Wiley and Sons,London 1978.
[2] Chanson, H. and Montes, J.S., “Over flow characteristics of cylindrical weirs”, Proc. ASCE, .Journal of irrigation and Drainage Engineering, vol. 124, No. 3, pp. 152-16),May,1998.
[3] Haveen M. Rashid “An Experimental Investigation of the coefficient of Discharge for circular and semi-circular weirs “, MSc Thesis, Dept. of Hydraulic Engineering, lUniversity of Sulaimania , Iraq ,2002
[4] Rokaia A.H. Al-Tikrity , ” Discharge coefficient For Semi-Circular Crested Rectangular weirs “. M.Sc. Thesis, Dept. of Civil Engineering, University of Tikrit, Iraq . 2000.
Tikrit Journal of Engineering Sciences (2006) 13(1) 82-96
Discharge Coefficient for Cylindrical Weirs
Rukaia A. Hussain | Sahar A. Mohammed |
Civil Eng. Dept., Tikrit University, Iraq | Civil Eng. Dept., kirkuk University, Iraq |
Abstract
The hydraulic characteristics of cylindrical weirs under free flow conditions were studied experimentally in order to investigate the discharge coefficient (Cd) and the influence of some significant factors and performance of weirs for discharge measuring. The experimental tests were carried out on three models of weirs in which the diameter of weir (D) was varied three times as: 8.0, 10.0 and 12.0 cm. For each model, a series of measurements were taken to measure coefficients of discharge. Results showed that the coefficient of discharge (Cd) increase with increasing the ratio of head to weir diameter (h/D),and for the same ratio (h/D), the discharge coefficient (Cd) increases with increasing weir diameter.
Download Full-text PDF
Keywords: Discharge Coefficient, Cylindrical Weirs.