vol14no4pa5

References

[1] William C. Cohen & Ernest F. Johnson, “Dynamic Characteristics of Double-Pipe Heat Exchanger “, Industrial and Engineering Chemistry, Vol. 48, No. 6, p. 1031-1034, 1956.

[2] Roetzel, W. & Xuan, Y. “Transient Response of Parallel and Counterflow Heat Exchanger”, ASME J. Heat Transfer, 114(2), May, p. 510-511 (1992).

[3] Lakshmann, C. C., “Dynamic Simulation of a Countercurrent Heat Exchanger Modeling Start-up and Frequency Response “, Int. Comm. Heat Transfer, 21(3), May-June, p. 421-43 (1994).
[4] Kahn, A. R., Baker, N. S., and Wardle, A. P.,” The Dynamic Characteristics of a Countercurrent Plate Heat Exchanger “, Int. J. Heat Transfer, 31(6), p. 1269-1278 (1988).

Tikrit Journal of Engineering Sciences (2007) 14(4) 87-103

Dynamic Behavior of Plate Heat Exchanger

Duraid Fadhel Ahmed
Chemical Eng. Dept., Tikrit University, Iraq

Abstract

The mathematical modeling of plate heat exchanger was studied by introducing rectangular pulse change in inlet cold water flow rate and measuring the temperature of outlet cold water. A theoretical model for the plate heat exchanger was developed based on the heat balance and used the frequency response analysis techniques to determine the best model parameters. The results show that the dynamic behavior of plate heat exchanger can be approximated by a time delay with first order system and a closed fit between the theoretical coefficients of the system and these data by using frequency response method.

Download Full-text PDF

KeywordsPlate Heat Exchanger, Frequency Analysis, Mathematical Model.

How to cite

TJES: Ahmed DF. Dynamic Behavior of Plate Heat ExchangerTikrit Journal of Engineering Sciences 2007; 14(4): 87-103.
APA: Ahmed, D. F. (2007). Dynamic Behavior of Plate Heat Exchanger. Tikrit Journal of Engineering Sciences, 14(4), 87-103.
Loader Loading...
EAD Logo Taking too long?
Reload Reload document
| Open Open in new tab

Download