vol25no3pa1

Hasan GT, Salih MO, Mutlaq AH. Study the effect of serial inductance on reducing the current harmonic distortion of three-phase bridge rectifier. Tikrit Journal of Engineering Sciences 2018; 25 (3): 1-4.              TJES
Hasan, G. T., Salih, M. O., & Mutlaq, A. H. (2018). Study the effect of serial inductance on reducing the current harmonic distortion of three-phase bridge rectifier. Tikrit Journal of Engineering Sciences, 25(3), 1-4.       APA

References

[1] Laaksonen M. Fourier’n menetelmät. Lecture handout. Tampere University of Technology; Tampere, Finland: 2013.
[2] Baggini A. Handbook of power quality. Chichester, West Sussex, England: John Wiley & Sons; 2008.
[3] Saastamoinen J. Jännitetasojen vertailu laivan sähköverkossa. Ph.D. Thesis. Metropolia University of Applied Sciences; Helsinki & Vantaa & Espoo, Finland: 2013.
[4] Bhat AH, Agarwal P. Improved power quality AC/DC converters. Power Quality: InTech; 2011. pp. 271–310.

Tikrit Journal of Engineering Sciences (2018) 25(3) 1- 4

Study the Effect of Serial Inductance on Reducing the Current Harmonic Distortion of Three-Phase Bridge Rectifier

Ghanim Thiab Hasan Muhamad Omar Salih Ali Hlal Mutlaq
Oil & Minerals Eng. Coll., Tikrit University, Iraq Coll. of Eng., Tikrit University,  Iraq Technical Coll./ Kirkuk, Iraq

Abstract

The aim of this paper is to analyze the influence of adding serial inductance in AC side of the ‎‎3ph -6 pulse bridge rectifier on the reduction of harmonic distortion rate. A simulated model ‎with serial inductance was analyzed. The 3-phase 6-pulse diode bridge rectifier was chosen ‎because it corresponds to the operation of the 6-pulse thyristor bridge rectifier at maximum ‎load (while keeping the angle α = 0). Both the total harmonic distortion (THDi) and the ‎power factor (PF) for the circuit have been measured. The results obtained of the THDi has ‎been recorded for four values of serial inductance and results was compared with the (IEEE 519-1992) standard. Comparison results indicates ‎that for values of inductive reactance (Xi) up to 67% cause a reduction of THDi which is above the standard values, while for (Xi) more than 67% cause a reduction in THDi within the acceptable standard level. Analyzing of results prove that the adding of serial inductance at the AC ‎side leads to good reduction in harmonic distortion rate, but with some reduction in power ‎factor value, which results in some energy losses.

Download Full-text PDF

Keywords: Serial inductance, current harmonics distortion, bridge rectifier.