vol26no1pa7

TJES: Amer M. Ibrahim, Wissam D. Salman, Fahad M. Bahlol. Flexural Behavior of Concrete Composite Beams with New Steel Tube Section and Different Shear Connectors.Tikrit Journal of Engineering Sciences 2019; 26(1):51-61.

APA:Ibrahim, A. M., Salman, W. D., & Bahlol, F. M. (2019). Flexural Behavior of Concrete Composite Beams with New Steel Tube Section and Different Shear Connectors. Tikrit Journal of Engineering Sciences, 26(1), 51-61.

References

[1] IS 11384 Code of practice for composite construction in structural steel and concrete, [CED 38: Special Structures] (1985).

[2] Cluase ES. Shear connection in composite beams. Steel Construction Institue. 1990; 4(6).

[3] Johnson R, Molenstra  N. Partial Shear Connection in Composite Beams for Buildings. Proceedings of the Institution of Civil Engineers (1991).

[4] Al-Darzi  SY, Chen A, Conceptual design and analysis of steel-concrete composite bridges: State of the Art. Steel Structures 2006; 6:393-407.

[1]

[2] Abdulmajeed KS. Nonlinear analysis of simply supported composite steel-concrete beams. M.Sc. Thesis 2009; University of Baghdad. Baghdad, Iraq.

[3] Salman WD. Strength and behavior of composite steel tube concrete beam. Diyala Journal of Engineering Sciences 2015; 8 (2): 163-181.

[4] Ibrahim AI, Said AI, Mubarak MM. Structural behavior of composite reinforced concrete decks with life line steel tube systems. Diyala Journal of Engineering Sciences 2016; 9(3): 104-119.

[5] Abdul Razak O. Effect of linear and nonlinear behavior of shear connectors in composite beams. M.Sc. thesis 1997; Al-Mustansiriya University. Baghdad, Iraq.

[6]     IOS No. 45, Iraqi standard specification for aggregate (Icosqc). Baghdad, Iraq (1984).

[7]     IOS No. 5 Iraqi standard specification for Portland cements (Icosqc). Baghdad, Iraq (1984).

[8]     Eurocode2: Design of concrete structures, Part 1 -1: General Rules and Rules for Buildings, (2004).

[9]     EFNARC, Specification and guidelines for self-compacting concrete. EFNARC, UK, (2002).

 

Tikrit Journal of Engineering Sciences (2019) 26(1) 51-61

Flexural Behavior of Concrete Composite Beams with New Steel Tube Section and Different Shear Connectors

Amer M. Ibrahim*, Wissam D. Salman,  Fahad M. Bahlol

 Civil Engineering Department, Diyala University, Diyala, Iraq

* Corresponding author:Amer M. Ibrahim, E-mail:  Amereng76@yahoo.com

DOI: http://dx.doi.org/10.25130/tjes.26.1.07

Abstract

Hollow sections of steel are widely used in many engineering applications as structural members. This paper aims at studying the flexural behavior of a composite beams with steel tubes sections through a series of bending tests in order to study and examine the influence of the steel tube section shape, (square, rectangular and hexagonal) with the same shear connector type (headed stud or angle or perfobond) on its flexural behavior and the bending properties of these sections. As well as study the effect of different shear connectors types (headed stud, angle and perfobond) in the same steel tube sections (hexagonal, square, or rectangular) on the flexural behavior of the composite beams. The experimental program (in this work) has been divided into two groups, the first consists of nine specimens tests focusing on three types of steel section. Using shear stud first, angle at second, and perfobond at third as shear connector type. The second group consists of testing nine specimens of composite beams too. This group focuses on testing every steel section (hexagonal, square and rectangular) alone when using three types of shear connectors with it. All the specimens are of the same length, width and height (2000, 400 and 130) mm respectively. The tested steel tubes thickness was 2 mm, yield stress of 322 MPa and the ultimate strength was 390 MPa. The results showed that these shapes of hollow steel sections (hexagonal, square and rectangular) sustain the quality of services for the buildings, and these tested specimens are applicable by giving a distinctive strength and stiffness starting from 114 kN as ultimate load reaching to 170 kN. The experimental results proved that the perfobond and angle connector types are clearly effective shear connectors. Shear connector of the perfobond type  increased the ultimate load of the composite beams by (6.25-9.74) % compared with the stud shear connector.

Download Full-Text PDF

Keywords: Composite beams, Hollow section, Hexagonal section, angle, perfobond

How to cite

TJES: Amer M. Ibrahim, Wissam D. Salman, Fahad M. Bahlol. Flexural Behavior of Concrete Composite Beams with New Steel Tube Section and Different Shear Connectors. Tikrit Journal of Engineering Sciences 2019; 26(2):51-61.

APA: Ibrahim, A. M., Salman, W. D., & Bahlol, F. M. (2019). Flexural Behavior of Concrete Composite Beams with New Steel Tube Section and Different Shear Connectors. Tikrit Journal of Engineering Sciences, 26(1), 51-61.